Difference Between Fire Suppression System & Fire Sprinkler

Difference Between Fire Suppression System & Fire Sprinkler

Fire sprinkler and fire suppression system share a common purpose. Parts of their systems may look similar, fire sprinkler and suppression systems are different in the way they extinguish or control fires and their applications.

Extinguishing a Fire

When fire sprinkler and fire suppression systems detect heat, smoke, or both they activate. Fire sprinkler systems use water to extinguish or control flames and minimize the spread of a fire until firefighters arrive. Whereas the most common fire suppression systems use chemical, gaseous or foam agents to suppress a fire.

Fire Suppression System

Fire Sprinkler and Fire Suppression Applications

Fire sprinkler systems are ideal for everyday applications and to reduce property damage caused by a fire. When water can contain the specific type of fire facilities use fire sprinklers. In certain instances, a fire suppression system is the only option to extinguish a fire. It’s also a viable option in cases where water would cause irreparable damage to the property its intended to protect.

Common Types of Suppression Systems and Applications

FM 200 Fire Suppression

– Requires no cleanup, leaves no residue.
– Ideal for computer rooms, museums, historical archives, and many other applications.

Carbon Dioxide

– Work quickly, efficiently, gaseous agent extremely dangerous to humans
– Printing presses, spray booths, flammable liquid storage, and dip tanks

Wet Chemical Fire Suppression

– Forms vapor suppression foam, effectively preventing re-ignition
– Ideal for kitchen applications

Dry Chemical Suppression

Work quickly to extinguish flames caused by flammable and combustible liquids
Mechanical rooms, furnace rooms, flammable liquid storage areas.

Types of Fire Sprinkler Systems and Applications

Wet Pipe Sprinkler

– Always filled with water and ready to go
– Commonly found in office buildings, hotels, and high-rise buildings

Dry Pipe Sprinkler

– Fill with water when the system activates
– Ideal for unheated buildings such as warehouses

Deluge Sprinkler

– Sprinkler heads always open, pipes fill with water when activated
– Used in areas of high hazard such as aircraft hangars and chemical storage facilities

Pre-action Sprinkler

– Requires activation of supplemental fire detection system
– Ideal in situations where accidental activation could cause a large amount of damage such as in libraries, data centers, museums etc.

Despite their differences, both fire sprinkler and fire suppression system’s purpose is to control or extinguish a fire.

Based on the type of fire hazard and code requirements there’s a fire sprinkler or fire suppression system solution to fit your facility’s needs.